Header Logo

Connection

Srinivasan Vedantham to Radiation Dosage

This is a "connection" page, showing publications Srinivasan Vedantham has written about Radiation Dosage.
Connection Strength

2.431
  1. Tseng HW, Fu Z, Vedantham S. Simultaneous reduction of radiation dose and scatter-to-primary ratio using a truncated detector and advanced algorithms for dedicated cone-beam breast CT. Biomed Phys Eng Express. 2025 Mar 03; 11(2).
    View in: PubMed
    Score: 0.871
  2. Vedantham S, Shi L, Karellas A, O'Connell AM, Conover DL. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography. Phys Med Biol. 2013 Nov 21; 58(22):7921-36.
    View in: PubMed
    Score: 0.397
  3. Vedantham S, Shi L, Karellas A, Noo F. Dedicated breast CT: radiation dose for circle-plus-line trajectory. Med Phys. 2012 Mar; 39(3):1530-41.
    View in: PubMed
    Score: 0.353
  4. Tseng HW, Karellas A, Vedantham S. Dedicated cone-beam breast CT: Data acquisition strategies based on projection angle-dependent normalized glandular dose coefficients. Med Phys. 2023 Mar; 50(3):1406-1417.
    View in: PubMed
    Score: 0.186
  5. Tseng HW, Karellas A, Vedantham S. Radiation dosimetry of a clinical prototype dedicated cone-beam breast CT system with offset detector. Med Phys. 2021 Mar; 48(3):1079-1088.
    View in: PubMed
    Score: 0.164
  6. Vedantham S, Karellas A, Vijayaraghavan GR, Kopans DB. Digital Breast Tomosynthesis: State of the Art. Radiology. 2015 Dec; 277(3):663-84.
    View in: PubMed
    Score: 0.115
  7. O'Connell AM, Karellas A, Vedantham S. The potential role of dedicated 3D breast CT as a diagnostic tool: review and early clinical examples. Breast J. 2014 Nov-Dec; 20(6):592-605.
    View in: PubMed
    Score: 0.105
  8. Sechopoulos I, Vedantham S, Suryanarayanan S, D'Orsi CJ, Karellas A. Monte Carlo and phantom study of the radiation dose to the body from dedicated CT of the breast. Radiology. 2008 Apr; 247(1):98-105.
    View in: PubMed
    Score: 0.067
  9. Layman RR, Leng S, Boedeker KL, Burk LM, Dang H, Duan X, Jacobsen MC, Li B, Li K, Little K, Madhav P, Miller J, Nute JL, Giraldo JCR, Ruchala KJ, Tao S, Varchena V, Vedantham S, Zeng R, Zhang D. AAPM Task Group Report 299: Quality control in multi-energy computed tomography. Med Phys. 2024 Oct; 51(10):7012-7037.
    View in: PubMed
    Score: 0.052
  10. Tseng HW, Vedantham S, Karellas A. Cone-beam breast computed tomography using ultra-fast image reconstruction with constrained, total-variation minimization for suppression of artifacts. Phys Med. 2020 May; 73:117-124.
    View in: PubMed
    Score: 0.039
  11. Deng L, Yasar S, Ahmed MF, Jayarathna S, Feng P, Wei B, Vedantham S, Karellas A, Cho SH. Investigation of transmission computed tomography (CT) image quality and x-ray dose achievable from an experimental dual-mode benchtop x-ray fluorescence CT and transmission CT system. J Xray Sci Technol. 2019; 27(3):431-442.
    View in: PubMed
    Score: 0.035
  12. van der Marel K, Vedantham S, van der Bom IM, Howk M, Narain T, Ty K, Karellas A, Gounis MJ, Puri AS, Wakhloo AK. Reduced Patient Radiation Exposure during Neurodiagnostic and Interventional X-Ray Angiography with a New Imaging Platform. AJNR Am J Neuroradiol. 2017 Mar; 38(3):442-449.
    View in: PubMed
    Score: 0.031
  13. Sechopoulos I, Suryanarayanan S, Vedantham S, D'Orsi C, Karellas A. Computation of the glandular radiation dose in digital tomosynthesis of the breast. Med Phys. 2007 Jan; 34(1):221-32.
    View in: PubMed
    Score: 0.015
Connection Strength

The connection strength for concepts is the sum of the scores for each matching publication.

Publication scores are based on many factors, including how long ago they were written and whether the person is a first or senior author.