Header Logo

Boris Keil PhD

TitleAdjunct Professor
InstitutionUMass Chan Medical School
DepartmentRadiology
AddressUMass Chan Medical School
55 Lake Avenue North
Worcester MA 01655
Phone496413092568
vCardDownload vCard
    Other Positions
    InstitutionT.H. Chan School of Medicine
    DepartmentRadiology


    Collapse Biography 
    Collapse education and training
    Technische Hochschule Mittelhessen University of Applied Sciences, Friedberg, , GermanyMSCBiomedical Engineering
    Philipp University of Marburg, Marburg, , GermanyPHDBiomedical Science

    Collapse Bibliographic 
    Collapse selected publications
    Publications listed below are automatically derived from MEDLINE/PubMed and other sources, which might result in incorrect or missing publications. Faculty can login to make corrections and additions.
    Newest   |   Oldest   |   Most Cited   |   Most Discussed   |   Timeline   |   Field Summary   |   Plain Text
    PMC Citations indicate the number of times the publication was cited by articles in PubMed Central, and the Altmetric score represents citations in news articles and social media. (Note that publications are often cited in additional ways that are not shown here.) Fields are based on how the National Library of Medicine (NLM) classifies the publication's journal and might not represent the specific topic of the publication. Translation tags are based on the publication type and the MeSH terms NLM assigns to the publication. Some publications (especially newer ones and publications not in PubMed) might not yet be assigned Field or Translation tags.) Click a Field or Translation tag to filter the publications.
    1. Kutscha N, Mahmutovic M, Bhusal B, Vu J, Chemlali C, Hansen SJD, May MW, Knake S, Golestanirad L, Keil B. A deep brain stimulation-conditioned RF coil for 3T MRI. Magn Reson Med. 2025 Mar; 93(3):1411-1426. PMID: 39444303.
      Citations:    
    2. Ramos-Llord?n G, Park DJ, Kirsch JE, Scholz A, Keil B, Maffei C, Lee HH, Bilgic B, Edlow BL, Mekkaoui C, Yendiki A, Witzel T, Huang SY. Eddy current-induced artifact correction in high b-value ex vivo human brain diffusion MRI with dynamic field monitoring. Magn Reson Med. 2024 Feb; 91(2):541-557. PMID: 37753621.
      Citations:    
    3. Rodriguez Y, Elsaid NMH, Keil B, Galiana G. 3D FRONSAC with PSF reconstruction. J Magn Reson. 2023 Oct; 355:107544. PMID: 37672990.
      Citations:    
    4. Gruber B, Stockmann JP, Mareyam A, Keil B, Bilgic B, Chang Y, Kazemivalipour E, Beckett AJS, Vu AT, Feinberg DA, Wald LL. A 128-channel receive array for cortical brain imaging at 7?T. Magn Reson Med. 2023 12; 90(6):2592-2607. PMID: 37582214.
      Citations:    
    5. Lopez-Rios N, Gilbert KM, Papp D, Cereza G, Foias A, Rangaprakash D, May MW, Guerin B, Wald LL, Keil B, Stockmann JP, Barry RL, Cohen-Adad J. An 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7?Tesla. NMR Biomed. 2023 Nov; 36(11):e5002. PMID: 37439129.
      Citations:    
    6. Navarro de Lara LI, Stockmann JP, Meng Q, Keil B, Mareyam A, Ulu? I, Daneshzand M, Makarov S, Wald LL, Nummenmaa A. A novel whole-head RF coil design tailored for concurrent multichannel brain stimulation and imaging at 3T. Brain Stimul. 2023 Jul-Aug; 16(4):1021-1031. PMID: 37307872.
      Citations:    
    7. Ramos-Llord?n G, Park D, Kirsch JE, Scholz A, Keil B, Maffei C, Lee HH, Bilgi? B, Edlow BL, Mekkaoui C, Yendiki A, Witzel T, Huang SY. Eddy current-induced artifacts correction in high gradient strength diffusion MRI with dynamic field monitoring: demonstration in ex vivo human brain imaging. bioRxiv. 2023 Feb 16. PMID: 36824894.
      Citations:    
    8. Rios NL, Gilbert KM, Papp D, Cereza G, Foias A, Rangaprakash D, May MW, Guerin B, Wald LL, Keil B, Stockmann JP, Barry RL, Cohen-Adad J. 8-channel Tx dipole and 20-channel Rx loop coil array for MRI of the cervical spinal cord at 7 Tesla. bioRxiv. 2023 Feb 09. PMID: 36798276.
      Citations:    
    9. Ramos-Llord?n G, Lobos RA, Kim TH, Tian Q, Witzel T, Lee HH, Scholz A, Keil B, Yendiki A, Bilgi? B, Haldar JP, Huang SY. High-fidelity, high-spatial-resolution diffusion magnetic resonance imaging of ex vivo whole human brain at ultra-high gradient strength with structured low-rank echo-planar imaging ghost correction. NMR Biomed. 2023 02; 36(2):e4831. PMID: 36106429.
      Citations:    
    10. May MW, Hansen SJD, Mahmutovic M, Scholz A, Kutscha N, Guerin B, Stockmann JP, Barry RL, Kazemivalipour E, Gumbrecht R, Kimmlingen R, Adriany M, Chang Y, Triantafyllou C, Knake S, Wald LL, Keil B. A patient-friendly 16-channel transmit/64-channel receive coil array for combined head-neck MRI at 7 Tesla. Magn Reson Med. 2022 09; 88(3):1419-1433. PMID: 35605167.
      Citations:    
    11. Fan Q, Eichner C, Afzali M, Mueller L, Tax CMW, Davids M, Mahmutovic M, Keil B, Bilgic B, Setsompop K, Lee HH, Tian Q, Maffei C, Ramos-Llord?n G, Nummenmaa A, Witzel T, Yendiki A, Song YQ, Huang CC, Lin CP, Weiskopf N, Anwander A, Jones DK, Rosen BR, Wald LL, Huang SY. Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact. Neuroimage. 2022 07 01; 254:118958. PMID: 35217204.
      Citations:    
    12. Tian Q, Fan Q, Witzel T, Polackal MN, Ohringer NA, Ngamsombat C, Russo AW, Machado N, Brewer K, Wang F, Setsompop K, Polimeni JR, Keil B, Wald LL, Rosen BR, Klawiter EC, Nummenmaa A, Huang SY. Comprehensive diffusion MRI dataset for in vivo human brain microstructure mapping using 300 mT/m gradients. Sci Data. 2022 01 18; 9(1):7. PMID: 35042861.
      Citations:    
    13. Thapa B, Mareyam A, Stockmann J, Strasser B, Keil B, Hoecht P, Carp SA, Li X, Wang Z, Chang YV, Dietrich J, Uhlmann E, Cahill DP, Batchelor T, Wald L, Andronesi OC. In Vivo Absolute Metabolite Quantification Using a Multiplexed ERETIC-RX Array Coil for Whole-Brain MR Spectroscopic Imaging. J Magn Reson Imaging. 2022 07; 56(1):121-133. PMID: 34958166.
      Citations:    
    14. Stockmann JP, Arango NS, Witzel T, Mareyam A, Sappo C, Zhou J, Jenkins L, Craven-Brightman L, Milshteyn E, Davids M, Hoge WS, Sliwiak M, Nasr S, Keil B, Adalsteinsson E, Guerin B, White JK, Setsompop K, Polimeni JR, Wald LL. A 31-channel integrated "AC/DC" B0 shim and radiofrequency receive array coil for improved 7T MRI. Magn Reson Med. 2022 02; 87(2):1074-1092. PMID: 34632626.
      Citations:    
    15. Huang SY, Witzel T, Keil B, Scholz A, Davids M, Dietz P, Rummert E, Ramb R, Kirsch JE, Yendiki A, Fan Q, Tian Q, Ramos-Llord?n G, Lee HH, Nummenmaa A, Bilgic B, Setsompop K, Wang F, Avram AV, Komlosh M, Benjamini D, Magdoom KN, Pathak S, Schneider W, Novikov DS, Fieremans E, Tounekti S, Mekkaoui C, Augustinack J, Berger D, Shapson-Coe A, Lichtman J, Basser PJ, Wald LL, Rosen BR. Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome. Neuroimage. 2021 11; 243:118530. PMID: 34464739.
      Citations:    
    16. Scholz A, Etzel R, May MW, Mahmutovic M, Tian Q, Ramos-Llord?n G, Maffei C, Bilgi? B, Witzel T, Stockmann JP, Mekkaoui C, Wald LL, Huang SY, Yendiki A, Keil B. A 48-channel receive array coil for mesoscopic diffusion-weighted MRI of ex?vivo human brain on the 3 T connectome scanner. Neuroimage. 2021 09; 238:118256. PMID: 34118399.
      Citations:    
    17. Etzel R, Mekkaoui C, Ivshina ES, Reese TG, Sosnovik DE, Hansen SJD, Ghotra A, Kutscha N, Chemlali C, Wald LL, Mahnken AH, Keil B. Optimized 64-channel array configurations for accelerated simultaneous multislice acquisitions in 3T cardiac MRI. Magn Reson Med. 2021 10; 86(4):2276-2289. PMID: 34028882.
      Citations:    
    18. Wang F, Dong Z, Tian Q, Liao C, Fan Q, Hoge WS, Keil B, Polimeni JR, Wald LL, Huang SY, Setsompop K. In vivo human whole-brain Connectom diffusion MRI dataset at 760??m isotropic resolution. Sci Data. 2021 04 29; 8(1):122. PMID: 33927203.
      Citations:    
    19. Ghotra A, Kosakowski HL, Takahashi A, Etzel R, May MW, Scholz A, Jansen A, Wald LL, Kanwisher N, Saxe R, Keil B. A size-adaptive 32-channel array coil for awake infant neuroimaging at 3?Tesla MRI. Magn Reson Med. 2021 09; 86(3):1773-1785. PMID: 33829546.
      Citations:    
    20. Barry RL, Babu S, Anteraper SA, Triantafyllou C, Keil B, Rowe OE, Rangaprakash D, Paganoni S, Lawson R, Dheel C, Cernasov PM, Rosen BR, Ratai EM, Atassi N. Ultra-high field (7T) functional magnetic resonance imaging in amyotrophic lateral sclerosis: a pilot study. Neuroimage Clin. 2021; 30:102648. PMID: 33872993.
      Citations:    
    21. Richardson H, Gweon H, Dodell-Feder D, Malloy C, Pelton H, Keil B, Kanwisher N, Saxe R. Response patterns in the developing social brain are organized by social and emotion features and disrupted in children diagnosed with autism spectrum disorder. Cortex. 2020 04; 125:12-29. PMID: 31958654.
      Citations:    
    22. Golestanirad L, Kazemivalipour E, Keil B, Downs S, Kirsch J, Elahi B, Pilitsis J, Wald LL. Reconfigurable MRI coil technology can substantially reduce RF heating of deep brain stimulation implants: First in-vitro study of RF heating reduction in bilateral DBS leads at 1.5 T. PLoS One. 2019; 14(8):e0220043. PMID: 31390346.
      Citations:    
    23. Kazemivalipour E, Keil B, Vali A, Rajan S, Elahi B, Atalar E, Wald LL, Rosenow J, Pilitsis J, Golestanirad L. Reconfigurable MRI technology for low-SAR imaging of deep brain stimulation at 3T: Application in bilateral leads, fully-implanted systems, and surgically modified lead trajectories. Neuroimage. 2019 10 01; 199:18-29. PMID: 31096058.
      Citations:    
    24. Cohen MA, Dilks DD, Koldewyn K, Weigelt S, Feather J, Kell AJ, Keil B, Fischl B, Z?llei L, Wald L, Saxe R, Kanwisher N. Representational similarity precedes category selectivity in the developing ventral visual pathway. Neuroimage. 2019 08 15; 197:565-574. PMID: 31077844.
      Citations:    
    25. Golestanirad L, Angelone LM, Kirsch J, Downs S, Keil B, Bonmassar G, Wald LL. Reducing RF-induced Heating near Implanted Leads through High-Dielectric Capacitive Bleeding of Current (CBLOC). IEEE Trans Microw Theory Tech. 2019 Mar; 67(3):1265-1273. PMID: 31607756.
      Citations:    
    26. Golestanirad L, Kirsch J, Bonmassar G, Downs S, Elahi B, Martin A, Iacono MI, Angelone LM, Keil B, Wald LL, Pilitsis J. RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5?T and 3T: The role of surgical lead management. Neuroimage. 2019 01 01; 184:566-576. PMID: 30243973.
      Citations:    
    27. Golestanirad L, Rahsepar AA, Kirsch JE, Suwa K, Collins JC, Angelone LM, Keil B, Passman RS, Bonmassar G, Serano P, Krenz P, DeLap J, Carr JC, Wald LL. Changes in the specific absorption rate (SAR) of radiofrequency energy in patients with retained cardiac leads during MRI at 1.5T and 3T. Magn Reson Med. 2019 Jan; 81(1):653-669. PMID: 29893997.
      Citations:    
    28. Winkler SA, Warr PA, Stockmann JP, Mareyam A, Keil B, Watkins RD, Wald LL, Rutt BK. Comparision of new element designs for combined RF-Shim arrays at 7 T. Concepts Magn Reson Part B Magn Reson Eng. 2018 Feb; 48B(1). PMID: 30613196.
      Citations:    
    29. Atassi N, Xu M, Triantafyllou C, Keil B, Lawson R, Cernasov P, Ratti E, Long CJ, Paganoni S, Murphy A, Salibi N, Seethamraju R, Rosen B, Ratai EM. Ultra high-field (7tesla) magnetic resonance spectroscopy in Amyotrophic Lateral Sclerosis. PLoS One. 2017; 12(5):e0177680. PMID: 28498852.
      Citations:    
    30. Deen B, Richardson H, Dilks DD, Takahashi A, Keil B, Wald LL, Kanwisher N, Saxe R. Organization of high-level visual cortex in human infants. Nat Commun. 2017 01 10; 8:13995. PMID: 28072399.
      Citations:    
    31. Golestanirad L, Iacono MI, Keil B, Angelone LM, Bonmassar G, Fox MD, Herrington T, Adalsteinsson E, LaPierre C, Mareyam A, Wald LL. Construction and modeling of a reconfigurable MRI coil for lowering SAR in patients with deep brain stimulation implants. Neuroimage. 2017 02 15; 147:577-588. PMID: 28011252.
      Citations:    
    32. Ahveninen J, Chang WT, Huang S, Keil B, Kopco N, Rossi S, Bonmassar G, Witzel T, Polimeni JR. Intracortical depth analyses of frequency-sensitive regions of human auditory cortex using 7TfMRI. Neuroimage. 2016 Dec; 143:116-127. PMID: 27608603.
      Citations:    
    33. Bianciardi M, Toschi N, Polimeni JR, Evans KC, Bhat H, Keil B, Rosen BR, Boas DA, Wald LL. The pulsatility volume index: an indicator of cerebrovascular compliance based on fast magnetic resonance imaging of cardiac and respiratory pulsatility. Philos Trans A Math Phys Eng Sci. 2016 May 13; 374(2067). PMID: 27044992.
      Citations:    
    34. Golestanirad L, Keil B, Angelone LM, Bonmassar G, Mareyam A, Wald LL. Feasibility of using linearly polarized rotating birdcage transmitters and close-fitting receive arrays in MRI to reduce SAR in the vicinity of deep brain simulation implants. Magn Reson Med. 2017 04; 77(4):1701-1712. PMID: 27059266.
      Citations:    
    35. Triantafyllou C, Polimeni JR, Keil B, Wald LL. Coil-to-coil physiological noise correlations and their impact on functional MRI time-series signal-to-noise ratio. Magn Reson Med. 2016 12; 76(6):1708-1719. PMID: 26756964.
      Citations:    
    36. Fan Q, Witzel T, Nummenmaa A, Van Dijk KRA, Van Horn JD, Drews MK, Somerville LH, Sheridan MA, Santillana RM, Snyder J, Hedden T, Shaw EE, Hollinshead MO, Renvall V, Zanzonico R, Keil B, Cauley S, Polimeni JR, Tisdall D, Buckner RL, Wedeen VJ, Wald LL, Toga AW, Rosen BR. MGH-USC Human Connectome Project datasets with ultra-high b-value diffusion MRI. Neuroimage. 2016 Jan 01; 124(Pt B):1108-1114. PMID: 26364861.
      Citations:    
    37. Mahmood Z, McDaniel P, Gu?rin B, Keil B, Vester M, Adalsteinsson E, Wald LL, Daniel L. General design approach and practical realization of decoupling matrices for parallel transmission coils. Magn Reson Med. 2016 07; 76(1):329-39. PMID: 26228386.
      Citations:    
    38. Farivar R, Grigorov F, van der Kouwe AJ, Wald LL, Keil B. Dense, shape-optimized posterior 32-channel coil for submillimeter functional imaging of visual cortex at 3T. Magn Reson Med. 2016 07; 76(1):321-8. PMID: 26218835.
      Citations:    
    39. Duval T, McNab JA, Setsompop K, Witzel T, Schneider T, Huang SY, Keil B, Klawiter EC, Wald LL, Cohen-Adad J. In vivo mapping of human spinal cord microstructure at 300mT/m. Neuroimage. 2015 Sep; 118:494-507. PMID: 26095093.
      Citations:    
    40. Stockmann JP, Witzel T, Keil B, Polimeni JR, Mareyam A, LaPierre C, Setsompop K, Wald LL. A 32-channel combined RF and B0 shim array for 3T brain imaging. Magn Reson Med. 2016 Jan; 75(1):441-51. PMID: 25689977.
      Citations:    
    41. Ni J, Auriel E, Martinez-Ramirez S, Keil B, Reed AK, Fotiadis P, Gurol EM, Greenberg SM, Viswanathan A. Cortical localization of microbleeds in cerebral amyloid angiopathy: an ultra high-field 7T MRI study. J Alzheimers Dis. 2015; 43(4):1325-30. PMID: 25171715.
      Citations:    
    42. Fan Q, Nummenmaa A, Witzel T, Zanzonico R, Keil B, Cauley S, Polimeni JR, Tisdall D, Van Dijk KR, Buckner RL, Wedeen VJ, Rosen BR, Wald LL. Investigating the capability to resolve complex white matter structures with high b-value diffusion magnetic resonance imaging on the MGH-USC Connectom scanner. Brain Connect. 2014 Nov; 4(9):718-26. PMID: 25287963.
      Citations:    
    43. Sander CY, Keil B, Chonde DB, Rosen BR, Catana C, Wald LL. A 31-channel MR brain array coil compatible with positron emission tomography. Magn Reson Med. 2015 Jun; 73(6):2363-75. PMID: 25046699.
      Citations:    
    44. Eryaman Y, Guerin B, Keil B, Mareyam A, Herraiz JL, Kosior RK, Martin A, Torrado-Carvajal A, Malpica N, Hernandez-Tamames JA, Schiavi E, Adalsteinsson E, Wald LL. SAR reduction in 7T C-spine imaging using a "dark modes" transmit array strategy. Magn Reson Med. 2015 Apr; 73(4):1533-9. PMID: 24753012.
      Citations:    
    45. Zhao W, Cohen-Adad J, Polimeni JR, Keil B, Guerin B, Setsompop K, Serano P, Mareyam A, Hoecht P, Wald LL. Nineteen-channel receive array and four-channel transmit array coil for cervical spinal cord imaging at 7T. Magn Reson Med. 2014 Jul; 72(1):291-300. PMID: 23963998.
      Citations:    
    46. McNab JA, Edlow BL, Witzel T, Huang SY, Bhat H, Heberlein K, Feiweier T, Liu K, Keil B, Cohen-Adad J, Tisdall MD, Folkerth RD, Kinney HC, Wald LL. The Human Connectome Project and beyond: initial applications of 300 mT/m gradients. Neuroimage. 2013 Oct 15; 80:234-45. PMID: 23711537.
      Citations:    
    47. Janssens T, Keil B, Serano P, Mareyam A, McNab JA, Wald LL, Vanduffel W. A 22-channel receive array with Helmholtz transmit coil for anesthetized macaque MRI at 3 T. NMR Biomed. 2013 Nov; 26(11):1431-40. PMID: 23703859.
      Citations:    
    48. Anteraper SA, Whitfield-Gabrieli S, Keil B, Shannon S, Gabrieli JD, Triantafyllou C. Exploring functional connectivity networks with multichannel brain array coils. Brain Connect. 2013; 3(3):302-15. PMID: 23510203.
      Citations:    
    49. Cohen-Adad J, Zhao W, Keil B, Ratai EM, Triantafyllou C, Lawson R, Dheel C, Wald LL, Rosen BR, Cudkowicz M, Atassi N. 7-T MRI of the spinal cord can detect lateral corticospinal tract abnormality in amyotrophic lateral sclerosis. Muscle Nerve. 2013 May; 47(5):760-2. PMID: 23553571.
      Citations:    
    50. Keil B, Wald LL. Massively parallel MRI detector arrays. J Magn Reson. 2013 Apr; 229:75-89. PMID: 23453758.
      Citations:    
    51. Keil B, Blau JN, Biber S, Hoecht P, Tountcheva V, Setsompop K, Triantafyllou C, Wald LL. A 64-channel 3T array coil for accelerated brain MRI. Magn Reson Med. 2013 Jul; 70(1):248-58. PMID: 22851312.
      Citations:    
    52. Keil B, Alagappan V, Mareyam A, McNab JA, Fujimoto K, Tountcheva V, Triantafyllou C, Dilks DD, Kanwisher N, Lin W, Grant PE, Wald LL. Size-optimized 32-channel brain arrays for 3 T pediatric imaging. Magn Reson Med. 2011 Dec; 66(6):1777-87. PMID: 21656548.
      Citations:    
    53. Keil B, Wiggins GC, Triantafyllou C, Wald LL, Meise FM, Schreiber LM, Klose KJ, Heverhagen JT. A 20-channel receive-only mouse array coil for a 3 T clinical MRI system. Magn Reson Med. 2011 Aug; 66(2):584-95. PMID: 21433066.
      Citations:    
    54. Meise FM, Rivoire J, Terekhov M, Wiggins GC, Keil B, Karpuk S, Salhi Z, Wald LL, Schreiber LM. Design and evaluation of a 32-channel phased-array coil for lung imaging with hyperpolarized 3-helium. Magn Reson Med. 2010 Feb; 63(2):456-64. PMID: 20099333.
      Citations:    
    55. Hinton-Yates DP, Cury RC, Wald LL, Wiggins GC, Keil B, Seethmaraju R, Gangadharamurthy D, Ogilvy CS, Dai G, Houser SL, Stone JR, Furie KL. 3.0 T plaque imaging. Top Magn Reson Imaging. 2007 Oct; 18(5):389-400. PMID: 18025993.
      Citations:    
    Keil's Networks
    Click the
    Explore
    buttons for more information and interactive visualizations!
    Concepts (137)
    Explore
    _
    Similar People (60)
    Explore
    _
    Same Department Expand Description
    Explore
    _
    Physical Neighbors
    _