Susan Woskie to Isocyanates
This is a "connection" page, showing publications Susan Woskie has written about Isocyanates.
Connection Strength
3.382
-
Mellette MP, Bello D, Xue Y, Yost M, Bello A, Woskie S. Evaluation of Disposable Protective Garments against Isocyanate Permeation and Penetration from Polyurethane Anticorrosion Coatings. Ann Work Expo Health. 2019 05 21; 63(5):592-603.
Score: 0.625
-
Mellette MP, Bello D, Xue Y, Yost M, Bello A, Woskie S. Testing of Disposable Protective Garments Against Isocyanate Permeation From Spray Polyurethane Foam Insulation. Ann Work Expo Health. 2018 07 06; 62(6):754-764.
Score: 0.588
-
Woskie SR, Bello D, Gore RJ, Stowe MH, Eisen EA, Liu Y, Sparer JA, Redlich CA, Cullen MR. Comparison of task-based exposure metrics for an epidemiologic study of isocyanate inhalation exposures among autobody shop workers. J Occup Environ Hyg. 2008 Sep; 5(9):588-98.
Score: 0.297
-
Sparer J, Stowe MH, Bello D, Liu Y, Gore RJ, Youngs F, Cullen MR, Redlich CA, Woskie SR. Isocyanate exposures in autobody shop work: the SPRAY study. J Occup Environ Hyg. 2004 Sep; 1(9):570-81.
Score: 0.225
-
Woskie SR, Sparer J, Gore RJ, Stowe M, Bello D, Liu Y, Youngs F, Redlich C, Eisen E, Cullen M. Determinants of isocyanate exposures in auto body repair and refinishing shops. Ann Occup Hyg. 2004 Jul; 48(5):393-403.
Score: 0.221
-
Bello D, Streicher RP, Liu YC, Sparer J, Young F, Woskie SR. Field comparison of impingers and treated filters for sampling of total aliphatic isocyanates with the MAP reagent. AIHA J (Fairfax, Va). 2002 Nov-Dec; 63(6):790-6.
Score: 0.199
-
Bello D, Streicher RP, Woskie SR. Evaluation of the NIOSH draft method 5525 for determination of the total reactive isocyanate group (TRIG) for aliphatic isocyanates in autobody repair shops. National Institute for Occupational Safety and Health. J Environ Monit. 2002 Jun; 4(3):351-60.
Score: 0.193
-
Bello A, Xue Y, Gore R, Woskie S, Bello D. Exposures and urinary biomonitoring of aliphatic isocyanates in construction metal structure coating. Int J Hyg Environ Health. 2020 05; 226:113495.
Score: 0.165
-
Bello A, Xue Y, Gore R, Woskie S, Bello D. Assessment and control of exposures to polymeric methylene diphenyl diisocyanate (pMDI) in spray polyurethane foam applicators. Int J Hyg Environ Health. 2019 06; 222(5):804-815.
Score: 0.156
-
Harari H, Bello D, Woskie S, Redlich C. Development of an Interception Glove Sampler for Skin Exposures to Aromatic Isocyanates. Ann Occup Hyg. 2016 Nov; 60(9):1092-1103.
Score: 0.130
-
Redlich CA, Bello D, Woskie SR, Streicher RP. Measurements of airborne methylene diphenyl diisocyanate concentration in the U.S. workplace--comment. J Occup Environ Hyg. 2009 Nov; 6(11):D82-3; author reply D83-5.
Score: 0.081
-
Bello D, Redlich CA, Stowe MH, Sparer J, Woskie SR, Streicher RP, Hosgood HD, Liu Y. Skin exposure to aliphatic polyisocyanates in the auto body repair and refinishing industry: II. A quantitative assessment. Ann Occup Hyg. 2008 Mar; 52(2):117-24.
Score: 0.071
-
Liu Y, Bello D, Sparer JA, Stowe MH, Gore RJ, Woskie SR, Cullen MR, Redlich CA. Skin exposure to aliphatic polyisocyanates in the auto body repair and refinishing industry: a qualitative assessment. Ann Occup Hyg. 2007 Jul; 51(5):429-39.
Score: 0.069
-
Bello D, Herrick CA, Smith TJ, Woskie SR, Streicher RP, Cullen MR, Liu Y, Redlich CA. Skin exposure to isocyanates: reasons for concern. Environ Health Perspect. 2007 Mar; 115(3):328-35.
Score: 0.066
-
Bello D, Smith TJ, Woskie SR, Streicher RP, Boeniger MF, Redlich CA, Liu Y. An FTIR investigation of isocyanate skin absorption using in vitro guinea pig skin. J Environ Monit. 2006 May; 8(5):523-9.
Score: 0.063
-
Bello D, Woskie SR, Streicher RP, Stowe MH, Sparer J, Redlich CA, Cullen MR, Liu Y. A laboratory investigation of the effectiveness of various skin and surface decontaminants for aliphatic polyisocyanates. J Environ Monit. 2005 Jul; 7(7):716-21.
Score: 0.059
-
Bello D, Woskie SR, Streicher RP, Liu Y, Stowe MH, Eisen EA, Ellenbecker MJ, Sparer J, Youngs F, Cullen MR, Redlich CA. Polyisocyanates in occupational environments: a critical review of exposure limits and metrics. Am J Ind Med. 2004 Nov; 46(5):480-91.
Score: 0.057
-
Harari H, Bello D, Woskie S, Redlich CA. Assessment of personal inhalation and skin exposures to polymeric methylene diphenyl diisocyanate during polyurethane fabric coating. Toxicol Ind Health. 2022 Sep; 38(9):622-635.
Score: 0.048
-
Liu Y, Sparer J, Woskie SR, Cullen MR, Chung JS, Holm CT, Redlich CA. Qualitative assessment of isocyanate skin exposure in auto body shops: a pilot study. Am J Ind Med. 2000 Mar; 37(3):265-74.
Score: 0.041
-
Liu Y, Stowe MH, Bello D, Woskie SR, Sparer J, Gore R, Youngs F, Cullen MR, Redlich CA. Respiratory protection from isocyanate exposure in the autobody repair and refinishing industry. J Occup Environ Hyg. 2006 May; 3(5):234-49.
Score: 0.016
-
Redlich CA, Stowe MH, Wisnewski AV, Eisen EA, Karol MH, Lemus R, Holm CT, Chung JS, Sparer J, Liu Y, Woskie SR, Appiah-Pippim J, Gore R, Cullen MR. Subclinical immunologic and physiologic responses in hexamethylene diisocyanate-exposed auto body shop workers. Am J Ind Med. 2001 Jun; 39(6):587-97.
Score: 0.011