Manojkumar Saranathan to Algorithms
This is a "connection" page, showing publications Manojkumar Saranathan has written about Algorithms.
Connection Strength
1.932
-
Saranathan M, Khalighi MM, Glover GH, Pandit P, Rutt BK. Efficient Bloch-Siegert B1 (+) mapping using spiral and echo-planar readouts. Magn Reson Med. 2013 Dec; 70(6):1669-73.
Score: 0.278
-
Saranathan M, Rettmann DW, Hargreaves BA, Clarke SE, Vasanawala SS. DIfferential Subsampling with Cartesian Ordering (DISCO): a high spatio-temporal resolution Dixon imaging sequence for multiphasic contrast enhanced abdominal imaging. J Magn Reson Imaging. 2012 Jun; 35(6):1484-92.
Score: 0.260
-
Saranathan M, Bayram E, Worters PW, Glockner JF. A 3D balanced-SSFP Dixon technique with group-encoded k-space segmentation for breath-held non-contrast-enhanced MR angiography. Magn Reson Imaging. 2012 Feb; 30(2):158-64.
Score: 0.255
-
Datta R, Bacchus MK, Kumar D, Elliott MA, Rao A, Dolui S, Reddy R, Banwell BL, Saranathan M. Fast automatic segmentation of thalamic nuclei from MP2RAGE acquisition at 7 Tesla. Magn Reson Med. 2021 05; 85(5):2781-2790.
Score: 0.120
-
Pandey A, Yoruk U, Keerthivasan M, Galons JP, Sharma P, Johnson K, Martin DR, Altbach MI, Bilgin A, Saranathan M. Multiresolution imaging using golden angle stack-of-stars and compressed sensing for dynamic MR urography. J Magn Reson Imaging. 2017 07; 46(1):303-311.
Score: 0.092
-
Levine E, Daniel B, Vasanawala S, Hargreaves B, Saranathan M. 3D Cartesian MRI with compressed sensing and variable view sharing using complementary poisson-disc sampling. Magn Reson Med. 2017 05; 77(5):1774-1785.
Score: 0.087
-
Saranathan M, Rettmann DW, Hargreaves BA, Lipson JA, Daniel BL. Variable spatiotemporal resolution three-dimensional Dixon sequence for rapid dynamic contrast-enhanced breast MRI. J Magn Reson Imaging. 2014 Dec; 40(6):1392-9.
Score: 0.073
-
Sung K, Saranathan M, Daniel BL, Hargreaves BA. Simultaneous T(1) and B(1) (+) mapping using reference region variable flip angle imaging. Magn Reson Med. 2013 Oct; 70(4):954-61.
Score: 0.072
-
Moran CJ, Hargreaves BA, Saranathan M, Lipson JA, Kao J, Ikeda DM, Daniel BL. 3D T2-weighted spin echo imaging in the breast. J Magn Reson Imaging. 2014 Feb; 39(2):332-8.
Score: 0.070
-
Moran CJ, Saranathan M, Nnewihe AN, Granlund KL, Alley MT, Daniel BL, Hargreaves BA. High resolution images of the breast. Eur J Radiol. 2012 Sep; 81 Suppl 1:S101-3.
Score: 0.067
-
Hargreaves BA, Saranathan M, Sung K, Daniel BL. Accelerated breast MRI with compressed sensing. Eur J Radiol. 2012 Sep; 81 Suppl 1:S54-5.
Score: 0.067
-
Worters PW, Saranathan M, Xu A, Vasanawala SS. Inversion-recovery-prepared dixon bSSFP: initial clinical experience with a novel pulse sequence for renal MRA within a breathhold. J Magn Reson Imaging. 2012 Apr; 35(4):875-81.
Score: 0.064
-
Sinha N, Ramakrishnan AG, Saranathan M. Composite MR image reconstruction and unaliasing for general trajectories using neural networks. Magn Reson Imaging. 2010 Dec; 28(10):1468-84.
Score: 0.059
-
Sinha N, Saranathan M, Ramakrishnan AG. Improved k-t BLAST for fast fMR imaging. J Magn Reson. 2010 Jun; 204(2):273-80.
Score: 0.057
-
Saranathan M, Rettmann D, Bayram E, Lee C, Glockner J. Multiecho time-resolved acquisition (META): a high spatiotemporal resolution Dixon imaging sequence for dynamic contrast-enhanced MRI. J Magn Reson Imaging. 2009 Jun; 29(6):1406-13.
Score: 0.054
-
Saranathan M, Ramanan V, Gulati R, Venkatesan R. ANTHEM: anatomically tailored hexagonal MRI. Magn Reson Imaging. 2007 Sep; 25(7):1039-47.
Score: 0.046
-
Du YP, Saranathan M, Foo TK. An accurate, robust, and computationally efficient navigator algorithm for measuring diaphragm positions. J Cardiovasc Magn Reson. 2004; 6(2):483-90.
Score: 0.037
-
Keerthivasan MB, Saranathan M, Johnson K, Fu Z, Weinkauf CC, Martin DR, Bilgin A, Altbach MI. An efficient 3D stack-of-stars turbo spin echo pulse sequence for simultaneous T2-weighted imaging and T2 mapping. Magn Reson Med. 2019 07; 82(1):326-341.
Score: 0.027
-
Shaikh J, Stoddard PB, Levine EG, Roh AT, Saranathan M, Chang ST, Muelly MC, Hargreaves BA, Vasanawala SS, Loening AM. View-Sharing Artifact Reduction With Retrospective Compressed Sensing Reconstruction in the Context of Contrast-Enhanced Liver MRI for Hepatocellular Carcinoma (HCC) Screening. J Magn Reson Imaging. 2019 04; 49(4):984-993.
Score: 0.026
-
Saranathan M, Kushmerick MJ. ANDANTE, a novel frequency-selective adiabatic pulse. J Magn Reson B. 1996 Jan; 110(1):69-74.
Score: 0.021
-
Loening AM, Saranathan M, Ruangwattanapaisarn N, Litwiller DV, Shimakawa A, Vasanawala SS. Increased speed and image quality in single-shot fast spin echo imaging via variable refocusing flip angles. J Magn Reson Imaging. 2015 Dec; 42(6):1747-58.
Score: 0.020
-
Ruangwattanapaisarn N, Loening AM, Saranathan M, Litwiller DV, Vasanawala SS. Faster pediatric 3-T abdominal magnetic resonance imaging: comparison between conventional and variable refocusing flip-angle single-shot fast spin-echo sequences. Pediatr Radiol. 2015 Jun; 45(6):847-54.
Score: 0.020
-
Tourdias T, Saranathan M, Levesque IR, Su J, Rutt BK. Visualization of intra-thalamic nuclei with optimized white-matter-nulled MPRAGE at 7T. Neuroimage. 2014 Jan 01; 84:534-45.
Score: 0.018
-
Glockner JF, Saranathan M, Bayram E, Lee CU. Breath-held MR cholangiopancreatography (MRCP) using a 3D Dixon fat-water separated balanced steady state free precession sequence. Magn Reson Imaging. 2013 Oct; 31(8):1263-70.
Score: 0.018
-
Jordan CD, Saranathan M, Bangerter NK, Hargreaves BA, Gold GE. Musculoskeletal MRI at 3.0 T and 7.0 T: a comparison of relaxation times and image contrast. Eur J Radiol. 2013 May; 82(5):734-9.
Score: 0.016
-
Hardy CJ, Saranathan M, Zhu Y, Darrow RD. Coronary angiography by real-time MRI with adaptive averaging. Magn Reson Med. 2000 Dec; 44(6):940-6.
Score: 0.007